Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PNAS Nexus ; 3(3): pgae101, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38533109

RESUMO

Increasing extreme weather events require a corresponding increase in coastal protection. We show that architected materials, which have macroscopic properties that differ from those of their constituent components, can increase wave energy dissipation by more than an order of magnitude over both natural and existing artificial reefs, while providing a biocompatible environment. We present a search that optimized their design through proper hydrodynamic modeling and experimental testing, validated their performance, and characterized sustainable materials for their construction.

2.
Appl Phys A Mater Sci Process ; 129(7): 490, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37333570

RESUMO

Laser processing of diamond has become an important technique for fabricating next generation microelectronic and quantum devices. However, the realization of low taper, high aspect ratio structures in diamond remains a challenge. We demonstrate the effects of pulse energy, pulse number and irradiation profile on the achievable aspect ratio with 532 nm nanosecond laser machining. Strong and gentle ablation regimes were observed using percussion hole drilling of type Ib HPHT diamond. Under percussion hole drilling a maximum aspect ratio of 22:1 was achieved with 10,000 pulses. To reach aspect ratios on average 40:1 and up to 66:1, rotary assisted drilling was employed using > 2 M pulse accumulations. We additionally demonstrate methods of obtaining 0.1° taper angles via ramped pulse energy machining in 10:1 aspect ratio tubes. Finally, effects of laser induced damage are studied using confocal Raman spectroscopy with observation of up to 36% increase in tensile strain following strong laser irradiation. However, we report that upon application of 600 °C heat treatment, induced strain is reduced by up to ~ 50% with considerable homogenization of observed strain. Supplementary Information: The online version contains supplementary material available at 10.1007/s00339-023-06755-2.

3.
J Magn Reson ; 352: 107475, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37224586

RESUMO

The resolution of magic angle spinning (MAS) nuclear magnetic resonance (NMR) spectra remains bounded by the spinning frequency, which is limited by the material strength of MAS rotors. Since diamond is capable of withstanding 1.5-2.5x greater MAS frequencies, compared to state-of-the art zirconia, we fabricated rotors from single crystal diamond. When combined with bearings optimized for spinning with helium gas, diamond rotors could achieve the highest MAS frequencies to date. Furthermore, the excellent microwave transmission properties and thermal conductivity of diamond could improve sensitivity enhancements in dynamic nuclear polarization (DNP) experiments. The fabrication protocol we report involves novel laser micromachining and produced rotors that presently spin at ωr/2π = 111.000 ±â€¯0.004 kHz, with stable spinning up to 124 kHz, using N2 gas as the driving fluid. We present the first proton-detected 13C/15N MAS spectra recorded using diamond rotors, a critical step towards studying currently inaccessible ex-vivo protein samples with MAS NMR. Previously, the high aspect ratio of MAS rotors (∼10:1) precluded fabrication of MAS rotors from diamond.


Assuntos
Diamante , Micro-Ondas , Espectroscopia de Ressonância Magnética/métodos , Proteínas
4.
Soft Robot ; 10(4): 724-736, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36730716

RESUMO

In this study, we present a method to construct meter-scale deformable structures for underwater robotic applications by discretely assembling mechanical metamaterials. We address the challenge of scaling up nature-like deformable structures while remaining structurally efficient by combining rigid and compliant facets to form custom unit cells that assemble into lattices. The unit cells generate controlled local anisotropies that architect the global deformation of the robotic structure. The resulting flexibility allows better unsteady flow control that enables highly efficient propulsion and optimized force profile manipulations. We demonstrate the utility of this approach in two models. The first is a morphing beam snake-like robot that can generate thrust at specific anguilliform swimming parameters. The second is a morphing surface hydrofoil that, when compared with a rigid wing at the same angles of attack (AoAs), can increase the lift coefficient up to 0.6. In addition, in lower AoAs, the L∕D ratio improves by 5 times, whereas in higher angles it improves by 1.25 times. The resulting hydrodynamic performance demonstrates the potential to achieve accessible, scalable, and simple to design and assemble morphing structures for more efficient and effective future ocean exploration and exploitation.

5.
Cell ; 184(9): 2430-2440.e16, 2021 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-33784496

RESUMO

Genomically minimal cells, such as JCVI-syn3.0, offer a platform to clarify genes underlying core physiological processes. Although this minimal cell includes genes essential for population growth, the physiology of its single cells remained uncharacterized. To investigate striking morphological variation in JCVI-syn3.0 cells, we present an approach to characterize cell propagation and determine genes affecting cell morphology. Microfluidic chemostats allowed observation of intrinsic cell dynamics that result in irregular morphologies. A genome with 19 genes not retained in JCVI-syn3.0 generated JCVI-syn3A, which presents morphology similar to that of JCVI-syn1.0. We further identified seven of these 19 genes, including two known cell division genes, ftsZ and sepF, a hydrolase of unknown substrate, and four genes that encode membrane-associated proteins of unknown function, which are required together to restore a phenotype similar to that of JCVI-syn1.0. This result emphasizes the polygenic nature of cell division and morphology in a genomically minimal cell.


Assuntos
Proteínas de Bactérias/genética , Cromossomos Bacterianos/genética , DNA Bacteriano/genética , Genoma Bacteriano , Mycoplasma/genética , Biologia Sintética/métodos , Proteínas de Bactérias/antagonistas & inibidores , Sistemas CRISPR-Cas , Engenharia Genética
6.
Sci Adv ; 6(47)2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33208371

RESUMO

Mechanical metamaterials offer exotic properties based on local control of cell geometry and their global configuration into structures and mechanisms. Historically, these have been made as continuous, monolithic structures with additive manufacturing, which affords high resolution and throughput, but is inherently limited by process and machine constraints. To address this issue, we present a construction system for mechanical metamaterials based on discrete assembly of a finite set of parts, which can be spatially composed for a range of properties such as rigidity, compliance, chirality, and auxetic behavior. This system achieves desired continuum properties through design of the parts such that global behavior is governed by local mechanisms. We describe the design methodology, production process, numerical modeling, and experimental characterization of metamaterial behaviors. This approach benefits from incremental assembly, which eliminates scale limitations, best-practice manufacturing for reliable, low-cost part production, and interchangeability through a consistent assembly process across part types.

7.
Science ; 368(6497): 1352-1357, 2020 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-32554592

RESUMO

Electrochemistry offers opportunities to promote single-electron transfer (SET) redox-neutral chemistries similar to those recently discovered using visible-light photocatalysis but without the use of an expensive photocatalyst. Herein, we introduce a microfluidic redox-neutral electrochemistry (µRN-eChem) platform that has broad applicability to SET chemistry, including radical-radical cross-coupling, Minisci-type reactions, and nickel-catalyzed C(sp2)-O cross-coupling. The cathode and anode simultaneously generate the corresponding reactive intermediates, and selective transformation is facilitated by the rapid molecular diffusion across a microfluidic channel that outpaces the decomposition of the intermediates. µRN-eChem was shown to enable a two-step gram-scale electrosynthesis of a nematic liquid crystal compound, demonstrating its practicality.

8.
Breast Cancer Res Treat ; 180(2): 343-357, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32020431

RESUMO

PURPOSE: The goal of breast cancer surgery is to remove all of the cancer with a minimum of normal tissue, but absence of full 3-dimensional information on the specimen makes this difficult to achieve. METHOD: Micro-CT is a high resolution, X-ray, 3D imaging method, widely used in industry but rarely in medicine. RESULTS: We imaged and analyzed 173 partial mastectomies (129 ductal carcinomas, 14 lobular carcinomas, 28 DCIS). Imaging was simple and rapid. The size and shape of the cancers seen on Micro-CT closely matched the size and shape of the cancers seen at specimen dissection. Micro-CT images of multicentric/multifocal cancers revealed multiple non-contiguous masses. Micro-CT revealed cancer touching the specimen edge for 93% of the 114 cases judged margin positive by the pathologist, and 28 of the cases not seen as margin positive on pathological analysis; cancer occupied 1.55% of surface area when both the pathologist and Micro-CT suggested cancer at the edge, but only 0.45% of surface area for the "Micro-CT-Only-Positive Cases". Thus, Micro-CT detects cancers that touch a very small region of the specimen surface, which is likely to be missed on sectioning. CONCLUSIONS: Micro-CT provides full 3D images of breast cancer specimens, allowing one to identify, in minutes rather than hours, while the patient is in OR, margin-positive cancers together with information on where the cancer touches the edge, in a fashion more accurate than possible from the histology slides alone.


Assuntos
Neoplasias da Mama/patologia , Carcinoma Ductal/patologia , Carcinoma Lobular/patologia , Imageamento Tridimensional/métodos , Mastectomia Segmentar/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Microtomografia por Raio-X/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Carcinoma Ductal/diagnóstico por imagem , Carcinoma Ductal/cirurgia , Carcinoma Lobular/diagnóstico por imagem , Carcinoma Lobular/cirurgia , Feminino , Humanos , Período Intraoperatório , Margens de Excisão , Estadiamento de Neoplasias , Manejo de Espécimes
9.
Soft Robot ; 4(1): 33-48, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28289574

RESUMO

We describe an approach for the discrete and reversible assembly of tunable and actively deformable structures using modular building block parts for robotic applications. The primary technical challenge addressed by this work is the use of this method to design and fabricate low density, highly compliant robotic structures with spatially tuned stiffness. This approach offers a number of potential advantages over more conventional methods for constructing compliant robots. The discrete assembly reduces manufacturing complexity, as relatively simple parts can be batch-produced and joined to make complex structures. Global mechanical properties can be tuned based on sub-part ordering and geometry, because local stiffness and density can be independently set to a wide range of values and varied spatially. The structure's intrinsic modularity can significantly simplify analysis and simulation. Simple analytical models for the behavior of each building block type can be calibrated with empirical testing and synthesized into a highly accurate and computationally efficient model of the full compliant system. As a case study, we describe a modular and reversibly assembled wing that performs continuous span-wise twist deformation. It exhibits high performance aerodynamic characteristics, is lightweight and simple to fabricate and repair. The wing is constructed from discrete lattice elements, wherein the geometric and mechanical attributes of the building blocks determine the global mechanical properties of the wing. We describe the mechanical design and structural performance of the digital morphing wing, including their relationship to wind tunnel tests that suggest the ability to increase roll efficiency compared to a conventional rigid aileron system. We focus here on describing the approach to design, modeling, and construction as a generalizable approach for robotics that require very lightweight, tunable, and actively deformable structures.

10.
Science ; 341(6151): 1219-21, 2013 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-23950496

RESUMO

We introduce composite materials made by reversibly assembling a three-dimensional lattice of mass-produced carbon fiber-reinforced polymer composite parts with integrated mechanical interlocking connections. The resulting cellular composite materials can respond as an elastic solid with an extremely large measured modulus for an ultralight material (12.3 megapascals at a density of 7.2 milligrams per cubic centimeter). These materials offer a hierarchical decomposition in modeling, with bulk properties that can be predicted from component measurements and deformation modes that can be determined by the placement of part types. Because site locations are locally constrained, structures can be produced in a relative assembly process that merges desirable features of fiber composites, cellular materials, and additive manufacturing.

11.
Science ; 327(5969): 1086-8, 2010 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-20185713
12.
Proc Natl Acad Sci U S A ; 104(22): 9198-203, 2007 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-17517654

RESUMO

We here report on the design of a planar microslot waveguide NMR probe with an induction element that can be fabricated at scales from centimeters to nanometers to allow analysis of biomolecules at nano- or picomole quantities, reducing the required amount of materials by several orders of magnitude. This device demonstrates the highest signal-to-noise ratio for a planar detector to date, measured by using the anomeric proton signal from a 15.6-nmol sample of sucrose. This probe had a linewidth of 1.1 Hz for pure water without susceptibility matching. Analysis of 1.57 nmol of ribonuclease-A shows high sensitivity in one- and two-dimensional NMR spectra. Along with reducing required sample volumes, this integrated geometry can be packed in parallel arrays and combined with microfluidic systems. Further development of this device may have broad implications not only for advancing our understanding of many intractable protein structures and their folding, molecular interactions, and dynamic behaviors, but also for high-sensitivity diagnosis of a number of protein conformational diseases.


Assuntos
Espectroscopia de Ressonância Magnética/instrumentação , Espectroscopia de Ressonância Magnética/métodos , Simulação por Computador , Sacarose/química , Água/química
13.
Science ; 315(5813): 832-5, 2007 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-17289994

RESUMO

We demonstrate universal computation in an all-fluidic two-phase microfluidic system. Nonlinearity is introduced into an otherwise linear, reversible, low-Reynolds number flow via bubble-to-bubble hydrodynamic interactions. A bubble traveling in a channel represents a bit, providing us with the capability to simultaneously transport materials and perform logical control operations. We demonstrate bubble logic AND/OR/NOT gates, a toggle flip-flop, a ripple counter, timing restoration, a ring oscillator, and an electro-bubble modulator. These show the nonlinearity, gain, bistability, synchronization, cascadability, feedback, and programmability required for scalable universal computation. With increasing complexity in large-scale microfluidic processors, bubble logic provides an on-chip process control mechanism integrating chemistry and computation.


Assuntos
Metodologias Computacionais , Técnicas Analíticas Microfluídicas , Microfluídica , Ação Capilar , Fenômenos Químicos , Físico-Química , Lógica , Matemática , Procedimentos Analíticos em Microchip , Dinâmica não Linear , Tensão Superficial
14.
Sci Am ; 291(4): 76-81, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15487673
15.
Science ; 297(5589): 2026-30, 2002 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-12242435

RESUMO

Modern cryptographic practice rests on the use of one-way functions, which are easy to evaluate but difficult to invert. Unfortunately, commonly used one-way functions are either based on unproven conjectures or have known vulnerabilities. We show that instead of relying on number theory, the mesoscopic physics of coherent transport through a disordered medium can be used to allocate and authenticate unique identifiers by physically reducing the medium's microstructure to a fixed-length string of binary digits. These physical one-way functions are inexpensive to fabricate, prohibitively difficult to duplicate, admit no compact mathematical representation, and are intrinsically tamper-resistant. We provide an authentication protocol based on the enormous address space that is a principal characteristic of physical one-way functions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...